Promise, Precision and Penetration.

MagicTouch SCB is a Sirolimus Drug Coated Balloon catheter for the treatment of the coronary arteries: intended for treating In-Stent Restenosis, Small Vessels, Bifurcations lesions and De-Novo lesions.
Received 2 US FDA IDE Approval for Small Vessels & In-Stent Restenosis Indications 2 IDE clinical trials underway with patient enrollment initiated
02
-
De Novo Lesions
- Advanced approach for high-risk restenosis patients
- Innovative therapy minimizing residue, improving long-term outcomes
- Designed for those with inherent disease and comorbidities
-
In Stent Restenosis
- Resolves restenosis with even drug distribution
- Avoids additional metal load in diffuse, focal and edge stenosis
-
Small Vessels
- Effectively treats narrow anatomies while preserving lumen diameter
-
Bifurcation Lesions
- Reduces metal-to-artery ratio with a single-stent technique
03
Nanolute is an advanced drug delivery technology designed to enhance the efficiency of drug administration and retention, enabling sustained delivery from non-implantable devices. Nanolute is capable of delivering drugs effectively, regardless of whether their lipophilicity is poor or high.

Unique coating technology
REFOLDING
3 Folds
TECHNOLOGY
An innovative proprietary Nanolute technology providing better bioavailability of SIROLIMUS
Sirolimus: A drug with proven safety profile
COATING
Unique coating technology leads to 100% balloon surface coating
CARRIER
A biocompatible phospholipid drug carrier improving the adhesion property of Sirolimus
05
Drug/Excipient
Drug | Sirolimus |
Drug Dose | 1.27 μg/mm² |
Drug Carrier | Phospholipid |
Balloon
Balloon Material | Polyamide |
Catheter Desing | RX/Monorail |
No. of Folds | 3** |
Compliance | Semi -compliant |
Delivery System
Shaft Diameter-Proximal | 1.95F |
Shaft Diameter-Distal | 2.67F |
Usable Catheter Length | 140cm |
Tip Profile | 0.016” |
Nominal Pressure | 6 bar |
Rated Burst Pressure | 16 bar* |
Guiding Catheter Compatibility | 6F |
Guidewire Compatibility | 0.014” maximum recommended |
Crossing Profile(varies With Size) | 0.029 |
DRUG/EXCIPIENT
Drug
Drug Dose
Drug Carrier
1.27µg/mm²
Phospholipid
Catheter design
Rapid Exchange(RX) Design
Diameter (mm) | Balloon Length (mm) | ||||||
---|---|---|---|---|---|---|---|
10 | 15 | 20 | 25 | 30 | 35 | 40 | |
1.50 | CMT15010 | CMT15015 | CMT15020 | CMT15025 | CMT15030 | CMT15035 | CMT15040 |
2.00 | CMT20010 | CMT20015 | CMT20020 | CMT20025 | CMT20030 | CMT20035 | CMT20040 |
2.25 | CMT22510 | CMT22515 | CMT22520 | CMT22525 | CMT22530 | CMT22535 | CMT22540 |
2.50 | CMT25010 | CMT25015 | CMT25020 | CMT25025 | CMT25030 | CMT25035 | CMT25040 |
2.75 | CMT27510 | CMT27515 | CMT27520 | CMT27525 | CMT27530 | CMT27535 | CMT27540 |
3.00 | CMT30010 | CMT30015 | CMT30020 | CMT30025 | CMT30030 | CMT30035 | CMT30040 |
3.50 | CMT35010 | CMT35015 | CMT35020 | CMT35025 | CMT35030 | CMT35035 | CMT35040 |
4.00 | CMT40010 | CMT40015 | CMT40020 | CMT40025 | CMT40030 | CMT40035 | CMT40040 |
Balloon Diameter (mm) | Balloon Length (mm) | ||||||
---|---|---|---|---|---|---|---|
10 | 15 | 20 | 25 | 30 | 35 | 40 | |
1.50 | CMN15010 | CMN15015 | CMN15020 | CMN15025 | CMN15030 | CMN15035 | CMN15040 |
2.00 | CMN20010 | CMN20015 | CMN20020 | CMN20025 | CMN20030 | CMN20035 | CMN20040 |
2.25 | CMN22510 | CMN22515 | CMN22520 | CMN22525 | CMN22530 | CMN22535 | CMN22540 |
2.50 | CMN25010 | CMN25015 | CMN25020 | CMN25025 | CMN25030 | CMN25035 | CMN25040 |
2.75 | CMN27510 | CMN27515 | CMN27520 | CMN27525 | CMN27530 | CMN27535 | CMN27540 |
3.00 | CMN30010 | CMN30015 | CMN30020 | CMN30025 | CMN30030 | CMN30035 | CMN30040 |
3.25 | CMN32510 | CMN32515 | CMN32520 | CMN32525 | CMN32530 | CMN32535 | CMN32540 |
3.50 | CMN35010 | CMN35015 | CMN35020 | CMN35025 | CMN35030 | CMN35035 | CMN35040 |
4.00 | CMN40010 | CMN40015 | CMN40020 | CMN40025 | CMN40030 | CMN40035 | CMN40040 |